Accident Summary Nr: 14296768 - EMPLOYEE BURIED IN TRENCH CAVE-IN

Accident Summary Nr: 14296768 -- Report ID: 0352440 -- Event Date: 07/28/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
281271707/29/198616230W. Stike Contracting, Inc.

Abstract: AT APPROXIMATELY 2 PM ON JULY 28, 1986, EMPLOYEE #1, A PIPE LAYER EMPLOYED BY THE W. STIKE CONTRACTING COMPANY OF 4702 ROCK ROAD, STREET, MARYLAND, WAS WORKING IN A 20 FOOT LONG TRENCH, 5 FEET WIDE AND 12 FEET DEEP, WHEN THE EAST SIDE CAVED IN AND COMPLEYELY BURIED HIM. HE WAS PREPARING TO CONNECT TWO 8 INCH PIECES OF SEWER PIPE. A STEEL TRENCH SHIELD WAS BEING USED TO SUPPORT THE TRENCH WALLS. THE SHIELD WAS 16 FEET LONG, 4 FEET WIDE AND 8 FEET DEEP. HOWEVER, THE TRENCH SHIELD LEFT THE BOTTOM 4 FEET OF THE TRENCH WALL UNSUPPORTED. A RAMMAY GAS-POWERED SHEEP FOOT TAMPER WAS BEING OPERATED NEAR THE TRENCH. THERE WAS ALSO CONSTANT VEHICULAR TRAFFIC ON A ROAD WHICH RAN PARALLEL, AND 25 FEET AWAY FROM, THE TRENCH. THE SOIL WAS SOFT AND UNSTABLE. IN FACT, THE TRENCH WAS DUG IN BACK FILL WHICH HAD BEEN PUT IN PLACE ONLY ABOUT A WEEK BEFORE. THE PRESENCE OF QUARTZ PARTICLES IN THE SOIL WAS ALSO PRONOUNCED. A LADDER OR STEPS WAS NOT PROVIDED FOR EMPLOYEES' USE IN LEAVING THE TRENCH.

Keywords: EXCAVATION, CONSTRUCTION, TRENCH, UNSTABLE SOIL, BURIED, CAVE-IN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2812717 Hospitalized injury Other Plumbers, pipefitters and steamfitters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close