Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14295216 - EMPLOYEE KILLED IN FALL FROM LINER TUB LIFTED BY FORKLIFT

Accident Summary Nr: 14295216 -- Report ID: 0355119 -- Event Date: 11/15/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
1874348411/16/198730110Goodyear Tire & Rubber Company

Abstract: AT APPROXIMATELY 8:30 AM ON NOVEMBER 15, 1987, EMPLOYEE #1 ENTERED A LINER TUB AND WAS LIFTED 12 FEET ABOVE THE FLOOR BY A FORKLIFT SO THAT HE COULD TURN OFF A HAND VALVE TO A STEAM LINE. WHEN THE EMPLOYEE TOOK A STEP FORWARD IN THE TUB, THE TUB TILTED DOWNWARD. EMPLOYEE #1 FELL OUT OF THE TUB TO THE CONCRETE FLOOR. HE WAS DECLARED DEAD ON ARRIVAL AT THE HOSPITAL FROM MASSIVE HEAD INJURIES. HE ALSO SUFFERED TWO BROKEN HANDS.

Keywords: FRACTURE, HEAD, UNSECURED, WORK RULES, INDUSTRIAL TRUCK, FALL, HAND, UNSTABLE POSITION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18743484 Fatality Fracture Plumbers, pipefitters and steamfitters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.