Accident Report Detail

Accident Summary Nr: 14294854 - Three employees injured in roof truss collapse

Accident Summary Nr: 14294854 -- Report ID: 0355114 -- Event Date: 05/31/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11237998705/31/199117510D & B Builders
Inspection NrDate OpenedSICNAICSEstablishment Name
11237997905/31/199117510Jite Construction Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
11237998705/31/199117510D & B Builders

Abstract: At approximately 7:10 a.m. on May 31, 1991, Employees #1 through #3 and a coworker had just finished setting 13 roof trusses for a townhouse unit under construction. Each of the approximately 387 lb trusses was 38 ft wide by 10 ft high and was constructed of southern yellow pine 2 by 4s and 2 by 6s. As a truss was erected it was nailed on each end and held up by a single row of metal strap bracing that went down each side of the row of trusses. The bracing also maintained the 24 in. spacing between the trusses. The initial truss had been braced to an adjoining unit using 10 ft long 2 by 4s and an 8 ft long 2 by 4. Once all the trusses were in place, the employees were installing additional bracing when Employee #3 heard a popping sound overhead and noticed the trusses moving. Both he and another employee shouted a warning, but their coworkers were unable to get out of the way in time. Employee #1 sustained a fractured right leg, Employee #2 sustained a fractured collarbone and scalp laceration, and Employee #3 sustained a dislocated left hip along with left knee ligament damage. All three also sustained various contusions and abrasions. The main causal factor appears to have been inadequate bracing of the trusses.

Keywords: FRACTURE, TRUSS, UNSECURED, WORK RULES, CONSTRUCTION, LACERATION, DISLOCATED, BRACING, HIP, LEG

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 112379987 Hospitalized injury Fracture Carpenters
2 112379987 Hospitalized injury Dislocation Carpenters
3 112379979 Occupation Not Listed
4 112379987 Hospitalized injury Fracture Carpenters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.