Accident Summary Nr: 14294755 - Welder Is Electrocuted While Using Mig Welder

Accident Summary Nr: 14294755 -- Report ID: 0355110 -- Event Date: 09/12/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
31231947809/12/20083532333131Mescher Manufacturing Co Inc

Abstract: On September 12, 2008, a welder installed a flow regulator on a cylinder of carbon dioxide, the shielding gas for the MIG welder he was using. The welder felt a shock from the MIG welder and asked a coworker to see if he could feel it. The coworker refused and went back to his work area. Shortly thereafter, the coworker heard a yell from the welder and saw him holding the ground clamp in one hand and the electrode holder in the other hand. Another coworker unplugged the welder. Once the MIG welder was unplugged, the welder fell to the floor. A coworker performed CPR on the welder until rescue personnel arrived. The welder was transported by ambulance to Buchanan County General Hospital, where he was pronounced dead from electrocution.

Keywords: INSTALLING, REGULATOR VALVE, CPR, WELDER, ELECTRIC SHOCK, FALL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 312319478 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close