Accident Report Detail
Accident Summary Nr: 14293690 - Employee injured when struck by broken mainline
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 123720641 | 03/04/1993 | 2411 | 0 | Mike Pihl Logging Company |
Abstract: At approximately 9:20 a.m. on March 2, at township 4N, range 2W, section 21 in Scappose, OR, a 3/4 in. mainline broke while it was pulling a tree-length log. Employee #1 and the other chaser was standing between the loader and the yarder when the mainline broke. An approximately 30 ft length of the 3/4 in. mainline flew through the air and struck the front of the yarder, then ricocheted off the equipment and struck Employee #1, who was standing closet to the yarder, on the left thigh, groin area, abdomen, and left arm. He was thrown backwards 5 feet. Employee #1 sustained bruises and minor lacerations, and the tip of his left thumb was fractured. When the hooktender whistled for the yarder to pull in the log, it became caught behind a stump. The hooktender then whistled to let off and then signaled for an immediate reverse. This created a snapping action to the mainline and it broke. The hooktender admits that he should have waited a couple of seconds to give the return whistle and Employee #1 admits that he should have been sheltered behind the loader or the yarder while waiting for that turn.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 123720641 | Hospitalized injury | Bruise/Contus/Abras | Timber cutting and logging occupations |