Accident Summary Nr: 14291751 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

Accident Summary Nr: 14291751 -- Report ID: 0355118 -- Event Date: 06/22/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
10575878306/23/198932710Virginia Block, Inc.

Abstract: TWO EMPLOYEES ARRIVED AT A HOUSING CONSTRUCTION SITE. THEY WERE DELIVERING A LOAD OF CINDER BLOCK AND WINDOW AND DOOR LINTELS. THEY WERE USING A BRICK BOOM TRUCK TO UNLOAD THE MATERIAL. ONE OF THE EMPLOYEES WAS STANDING ON THE GROUND, ABOUT 5 FEET FROM THE TRUCK, OPERATING THE BOOM THROUGH A CABLE-CONNECTED REMOTE CONTROL UNIT. THE CABLE FOR THE REMOTE CONTROL WAS 20 FEET LONG. WHILE HE WAS UNLOADING THE MATERIAL, THE BOOM CONTACTED A 7200-VOLT OVERHEAD POWER LINE, AND THE EMPLOYEE WAS ELECTROCUTED.

Keywords: BOOM TRUCK, OVERHEAD POWER LINE, ELECTRICAL, BOOM, ELECTROCUTED, E GI IA, TRUCK BOOM

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 105758783 Fatality Electric Shock Miscellaneous material moving equipment operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.