Accident Report Detail

Accident Summary Nr: 14291215 - Employee injured in fall from collapsing scissor lift

Accident Summary Nr: 14291215 -- Report ID: 0214700 -- Event Date: 01/15/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
10688270701/15/199317950Manorville Contracting Corp.

Abstract: At approximately 11:30 a.m. on January 8, 1993, Employee #1, a laborer, was burning a piece of steel 6 in. by 8 in. by 5 ft from a scissor lift elevated to approximately 7 ft 3 in. When the cut was nearly complete, the steel came down and became lodged in the lift's scissor mechanism, causing the lift to tip over and throw Employee #1 approximately 12 ft along the ground. He sustained a fractured hip and was hospitalized.

Keywords: FRACTURE, HOISTING MECHANISM, CONSTRUCTION, JAMMED, FALL, FALLING OBJECT, HIP, AERIAL LIFT, CUTTING AND BURNING, OVERTURN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 106882707 Hospitalized injury Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.