Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14289714 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU GUY

Accident Summary Nr: 14289714 -- Report ID: 0355111 -- Event Date: 05/07/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
10573479205/09/199017990Laidlaw Tree Service, Inc.

Abstract: An employee was clearing small saplings from around guys for utility poles supporting a 14.4-kilovolt overhead power line. He had cut several small saplings with a chain saw and then set it off to the side so that he could use both hands to remove the cut trees. The guy he was clearing had about 200 millimeters of slack in it. He apparently touched the guy with one hand while reaching underneath to clear the cut trees. As he pushed the guy to move it out of his way, it contacted the primary lead for a 10-kilovolt-ampere transformer on the pole. The employee was electrocuted. (The 1-ampere McGraw-Edison opened in response to the fault.)

Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, E PTD, GUY, TRANSFORMER, UTILITY POLE, TREE TRIMMING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 105734792 Fatality Electric Shock Construction trades, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.