Accident Summary Nr: 14286553 - Employee injured in fall from scaffold when struck by duct

Accident Summary Nr: 14286553 -- Report ID: 0214700 -- Event Date: 09/07/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
10751704709/07/199417110Powerhouse Sheet Metal Company Inc.

Abstract: Employee #1 was dismantling an HVAC duct system suspended from the ceiling while on an 8 ft tall mobile scaffold that was not fully planked or properly guarded. The wheels on the mobile scaffold were not locked. A section of the HVAC duct broke free of the ceiling, swung down, hit the mobile scaffold, and threw Employee #1 to the ground. He sustained a blood clot in the brain.

Keywords: BLOOD CLOT, DISMANTLING, MOBILE SCAFFOLD, UNSECURED, WORK RULES, CONSTRUCTION, FALL, STRUCK BY, BRAIN, UNGUARDED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 107517047 Hospitalized injury Concussion Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.