Accident Summary Nr: 142812.015 - Employee is impaled by wood, later dies

Accident Summary Nr: 142812.015 -- Report ID: 0626700 -- Event Date: 01/13/2022
Inspection NrDate OpenedSICNAICSEstablishment Name
1572946.01501/18/2022337121Benedettini Cabinets, Lp

Abstract: At 12:30 p.m. on January 13, 2022, an employee was in the rough mill submitting a request for a job for the framing department. The employee was standing behind a coworker while they were cutting wood, for a different order, on a straight line rip saw. The self-fed ripsaw was not equipped with an outer guard and the anti kickback fingers were not free flowing. A piece of wood kicked back, striking the employee and impaling her through the abdomen and into the arm. The employee was transported to the hospital with puncture wounds and died from her injuries six days later.

Keywords: Abdomen, Arm, Guard, Impaled, Kick Back, Rip, Saw, Wood

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1572946.015 63 F Fatality

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.