Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14269922 - EMPLOYEE KILLED AFTER BREATHING NITROGEN IN RESPIRATOR

Accident Summary Nr: 14269922 -- Report ID: 0134000 -- Event Date: 01/26/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
10281190801/29/199036740Digital Equipment Corp.
Inspection NrDate OpenedSICNAICSEstablishment Name
10281189001/31/199017960Cotter Corporation

Abstract: Digital Equipment Corporation had established a central breathing-air station to supply air line respirators in three plant locations. An outside contractor was connecting a fourth location to the existing system using a nitrogen gas purge while braising copper line. Employees at one of the existing air line locations were not notified of the work going on. As a result, Employee #1 plugged in his respirator and was killed when he breathed nearly pure nitrogen.

Keywords: NITROGEN, AIR LINE, RESPIRATOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 102811908 Fatality Asphyxia Occupation not reported
2 102811890 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.