Accident Summary Nr: 14262554 - Employees exposed to carbon monoxide emitting from buffer

Accident Summary Nr: 14262554 -- Report ID: 0452110 -- Event Date: 05/11/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
11594565105/14/199254110Save-A-Lot

Abstract: A defective propane-fired 5 hp floor buffer used in a Save-a-Lot grocery store was emitting high levels of carbon monoxide. Employees' carboxyhemoglobin levels elevated to 17 1/2 then to 23 percent approximately 2 to 3 hours after initial exposure. Employees #1, #2, and #3 were treated at the hospital emergency room. They were released when their carboxyhemoglobin levels returned to 3 to 5 percent; they returned to work the next day. The buffer was sent out for repair. It was emitting more than 230 ppm of carbon monoxide. A properly functioning buffer emits only 0 to 2 ppm.

Keywords: AIR CONTAMINATION, CARBON MONOXIDE, MECH MALFUNCTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 115945651 Non Hospitalized injury Asphyxia Cashiers
2 115945651 Non Hospitalized injury Asphyxia Cashiers
3 115945651 Non Hospitalized injury Asphyxia Cashiers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close