Accident Summary Nr: 14259154 - ASPHYXIATED IN A CONFINED SPACE

Accident Summary Nr: 14259154 -- Report ID: 0625700 -- Event Date: 08/10/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
73461608/13/198437690Martin Marietta Aerospace Corp Michoud Div

Abstract: EMPLOYEE #1 DROPPED AN ARTICLE THRU THE GRATING OF A COVERED PIT BELOW HIS WORK AREA. HE REMOVED THE PIT COVER AND DESCENDED THE LADDER TO THE PIT FLOOR TO RETRIEVE THE ARTICLE. HE DID NOT RETURN. THE PIT SURROUNDS THREE EMPTY CHEMICAL TANKS. THE TANKS HAD BEEN UNUSED AND TAGGED OUT FOR FIVE YEARS. THE CORONER'S DIAGNOSIS (THROUGH AN AUTOPSY) WAS "COMPRESSIVE ASPHYXIA". THIS INDICATES THAT THE EMPLOYEE WAS CAUGHT BETWEEN THE PIPES AND POSSIBLY OTHER STRUCTURES AND WAS UNABLE TO BREATHE. IT IS SUSPECTED THAT AN OXYGEN DEFICIENCY AND/OR CHLORINATED HYDROCARBON VAPORS WERE AT LEAST PARTIALLY RESPONSIBLE, BUT THIS COULD NOT BE SUBSTANTIATED. A SIMULATION OF THE WORK ENVIRONMENT PRIOR TO THE ACCIDENT PRODUCED NO DEFINITIVE RESULTS.

Keywords: ASPHYXIATED, CONFINED SPACE, PIT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 734616 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close