Accident Report Detail
Accident Summary Nr: 14257992 - Employee crushed to death in conveyor
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 102872868 | 03/28/1990 | 3086 | 0 | Carpenter Insulation |
Abstract: Employee #1 was guiding a piece into a conveyor. He was pulled into the conveyor and crushed between the bottom and the conveyor, which were adjusted to 1.3 inches apart. Employee #1 was killed.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 102872868 | Fatality | Other | Occupation not reported |