Accident Summary Nr: 14256911 - EMPLOYEE'S THUMB PARTIALLY AMPUTATED BY PUNCH PRESS

Accident Summary Nr: 14256911 -- Report ID: 0453710 -- Event Date: 08/07/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
1501473109/05/198437140Eaton Corp Air Controls Div

Abstract: EMPLOYEE #1 WAS OPERATING A TOLEDO MECHANICAL POWER PRESS (A FULL REVOLUTION PUNCH PRESS), ASSET NUMBER 1944. THE PRESS WAS LOCATED NEAR THE SOUTH WALL OF THE ASSEMBLY AREA, WHICH IS NEAR THE CENTER OF THE PLANT. AT THE TIME OF THE ACCIDENT THE PRESS WAS BEING USED TO IMPRINT THE PART NUMBER AND COMPANY IDENTIFICATION ON ONE-INCH DIAMETER BRASS PARTS. THE PRESS WAS OPERATING IN THE SINGLE-STROKE MODE, TO BE ACTIVATED BY A FOOT PEDAL. EMPLOYEE #1 WAS USING HER RIGHT HAND TO PLACE THE PARTS IN THE IMPACT AREA AND USING HER LEFT HAND TO REMOVE THEM. THE MACHINE IN QUESTION HAD BEEN OUT OF SERVICE FOR ABOUT 2 YEARS. DURING THIS TIME, THE TWO-HAND TRIP DEVICES HAD BEEN REMOVED FOR USE ELSEWHERE AND WERE NOT REPLACED. WHEN THE PRESS WAS PLACED BACK IN SERVICE THE DAY BEFORE THE ACCIDENT, THE SWEEPER ARM DEVICE WAS REMOVED TO ALLOW FOR INSERTION OF THE STAMPING DIE. NEITHER OF THESE DEVICES WERE REPLACED WHEN THE DIE WAS INSTALLED. THERE WAS ONLY A FOOT PEDAL, WITH GUARD, PLACED ON THE MACHINE TO ACTIVATE IT. EMPLOYEE #1 HAD APPROXIMATELY 15 YEARS EXPERIENCE WORKING WITH VARIOUS PUNCH PRESSES SIMILAR TO THE ONE INVOLVED IN THIS ACCIDENT. ON THE FIRST DAY THIS MACHINE WAS PLACED IN OPERATION, AT APPROXIMATELY 2 PM, THE RAM CLOSED WHILE EMPLOYEE #1'S HAND WAS PARTIALLY IN THE POINT OF OPERATION. THE TIP OF HER RIGHT THUMB WAS AMPUTATED.

Keywords: AMPUTATED, POWER PRESS, FOOT CONTROL, SWEEPER ARM, THUMB, TWO-HAND CONTROL, POINT OF OPERATION, PUNCH PRESS, PRESS, RAM

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 15014731 Hospitalized injury Amputation Punching and stamping press machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close