Accident Summary Nr: 14255459 - Employee's arm amputated when caught in snow truck roller

Accident Summary Nr: 14255459 -- Report ID: 0453710 -- Event Date: 02/27/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
300886903/11/198724930Masonite Corp.

Abstract: Employee #1 was attempting to remove ice and snow from the rotating drive roller of a conveyor on a snow truck. His glove became caught in the squeeze point and his right arm was pulled into the nip point and squeezed between the web-rubber belt and the drive roller. Employee #1's arm was amputated at the shoulder and he was hospitalized.

Keywords: MAINTENANCE, AMPUTATED, WORK RULES, CAUGHT BY, ROLLER CONVEYOR, ARM, NIP POINT, UNGUARDED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 3008869 Hospitalized injury Amputation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.