Accident Summary Nr: 14252340 - EMPLOYEES EXPOSED TO CHLORINE VAPORS

Accident Summary Nr: 14252340 -- Report ID: 0453710 -- Event Date: 08/19/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
299367308/20/198526310Champion International Corp

Abstract: AT APPROXIMATELY 11:30 AM ON AUGUST 19, 1985, A HOLDING TANK CONTAINING CHLORINE CONTAMINATED WATER RUPTURED. THE CHLORINE FROM THE ESCAPING WATER VAPORIZED, EXPOSING NUMEROUS EMPLOYEES OF THE CHAMPION AND B.E. AND K. COMPANIES TO CHLORINE GAS. EMPLOYEES #1 THROUGH #9 WERE EITHER TREATED AT THE CHAMPION FIRST AID STATION OR WERE SENT TO THE HOSPITAL.

Keywords: RESPIRATORY, INHALATION, RUPTURE, CHLORINE, TOXIC FUMES, TANK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2993673 Non Hospitalized injury Other Laborers, except construction
2 2993673 Non Hospitalized injury Other Laborers, except construction
3 2993673 Hospitalized injury Other Laborers, except construction
4 2993673 Hospitalized injury Other Laborers, except construction
5 2993673 Hospitalized injury Other Laborers, except construction
6 2993673 Non Hospitalized injury Other Laborers, except construction
7 2993673 Non Hospitalized injury Other Laborers, except construction
8 2993673 Non Hospitalized injury Other Laborers, except construction
9 2993673 Non Hospitalized injury Other Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.