Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14250971 - Employee killed when pulled into machine and crushed

Accident Summary Nr: 14250971 -- Report ID: 0453710 -- Event Date: 11/28/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
1857061411/30/198822810Fieldcrest Cannon, Inc.- Karastan Spinning

Abstract: At approximately 9:00 p.m. on November 28, 1988, Employee #1 was cleaning excess wool from a Proctor Schwartz wool drying machine before changing wool samples. The machine is used to dry raw wool after it is dyed. Employee #1 cleaned the spiked apron and the continuous extractor to keep wool colors and lots from mixing. While the machine was running, Employee #1 entered a 41 in. deep pit and tried to clean the wool from under the machine using a T-shaped tool. Employee #1 was caught by the machine's spiked teeth, which pulled him into the machine and crushed his arm, part of his chest, and part of his head. Employee #1 was killed.

Keywords: CHEST, HEAD, WORK RULES, CLEANING, CAUGHT BY, LOCKOUT, CRUSHED, PIT, ARM

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18570614 Fatality Asphyxia Miscellaneous textile machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close