Accident Summary Nr: 14250328 - RUN OVER BY MOTOR GRADER.

Accident Summary Nr: 14250328 -- Report ID: 0453710 -- Event Date: 08/26/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
1498902411/25/198591900Nc Dot Div Of Highways Division 12

Abstract: EMPLOYEE #1 WAS ASSISTING A MECHANIC REPAIR A BACK-UP ALARM ON A GRADER AT THE TIME OF THE ACCIDENT. EMPLOYEE #1 WAS STANDING AT THE REAR OF THE GRADER. THE MECHANIC WAS BESIDE THE ENGINE BETWEEN THE TANDEM WHEELS. THE MECHANIC ACCIDENTLY ENERGIZED THE STARTER RELAY, STARTING THE ENGINE. THE MACHINE WAS NOT LOCKED OUT. THE ENGINE STARTED IN THIRD GEAR REVERSE, WITH THE THROTTLE IN THE HIGH-SPEED POSITION. THE GRADER STARTED, TRAVELLING IN REVERSE. THE RIGHT TANDEM WHEELS RAN OVER EMPLOYEE #1, CAUSING INJURIES FROM WHICH HE DIED THREE WEEKS LATER. THE ENGINE ENABLING SWITCH HAD BEEN LEFT "ON", ENABLING THE ENGINE TO START. THE THROTTLES WERE IN THE FULLY OPEN POSITON, ALLOWING MAXIMUM ENGINE SPEED FOR TRAVELING.

Keywords: BACK-UP ALARM, GRADER, MAINTENANCE, LOCKOUT, STARTED IN GEAR, RUN OVER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 14989024 Fatality Other Grader, dozer and scraper operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close