Accident Summary Nr: 14249965 - EMPLOYEES BECAME ILL FROM CARBON MONOXIDE EXPOSURE

Accident Summary Nr: 14249965 -- Report ID: 0453710 -- Event Date: 01/21/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
305708001/23/198617110Schneider Sheet Metal
Inspection NrDate OpenedSICNAICSEstablishment Name
305707201/23/198617110Associated Mechanical Contractors Inc
Inspection NrDate OpenedSICNAICSEstablishment Name
305706401/23/198615410Morrison-Knudsen Inc
Inspection NrDate OpenedSICNAICSEstablishment Name
305708001/23/198617110Schneider Sheet Metal
Inspection NrDate OpenedSICNAICSEstablishment Name
305705601/23/198617310Skyline Construction Inc
Inspection NrDate OpenedSICNAICSEstablishment Name
305706401/23/198615410Morrison-Knudsen Inc
Inspection NrDate OpenedSICNAICSEstablishment Name
305707201/23/198617110Associated Mechanical Contractors Inc

Abstract: NINE EMPLOYEES, INCLUDING TWO WELDERS AND A HELPER, THREE SHEET METAL WORKERS, TWO PIPEFITTERS AND AN ELECTRICIAN BECAME ILL FROM EXPOSURE TO CARBON MONOXIDE BEING GENERATED BY INDUSTRIAL TRUCKS. THEY EXPERIENCED NAUSEA, HEADACHES, DIZZINESS, WEAKNESS AND BREATHING DIFFICULTIES. SIX OF THE EMPLOYEES HAD TO BE HOSPITALIZED.

Keywords: RESPIRATORY, TOXIC ATMOSPHERE, CARBON MONOXIDE, VENTILATION, HEADACHE, INHALATION, INDUSTRIAL TRUCK, DIZZINESS, CONSTRUCTION, NAUSEA

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 3057080 Hospitalized injury Asphyxia Sheet metal workers
2 3057072 Hospitalized injury Asphyxia Sheet metal workers
3 3057064 Hospitalized injury Asphyxia Welders and cutters
4 3057080 Non Hospitalized injury Asphyxia Plumber, pipefitter and steamfiter apprentices
5 3057056 Hospitalized injury Asphyxia Sheet metal workers
6 3057056 Hospitalized injury Asphyxia Plumber, pipefitter and steamfiter apprentices
7 3057064 Hospitalized injury Asphyxia Welders and cutters
8 3057064 Hospitalized injury Asphyxia Electricians
9 3057072 Hospitalized injury Asphyxia Plumbers, pipefitters and steamfitters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close