Accident Summary Nr: 14237747 - Employee killed in fall from derrick

Accident Summary Nr: 14237747 -- Report ID: 0627100 -- Event Date: 07/01/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
71327107/02/198613890Reliance Well Service

Abstract: Employee #1, a derrickman, was a member of a well service rig crew that was pulling sucker rods from an oil well to replace a pump unit. Thirty thribble sections, each measuring 75 ft, had been pulled and racked in the derrick. The operator apparently miscounted the number of connections for the rod as it came out of the hole; thinking it was the second box (connection) instead of the third, he continued to pull. The rig did not have an anti-two-blocking device, so the traveling block was pulled into the crown block, snapping the 1 in. wire rope. The traveling block and string of rod fell, knocking Employee #1 from the rod basket of the derrick. He fell 78 ft and struck against the block. Employee #1 died of massive fractures and injuries.

Keywords: DERRICK, WORK RULES, OIL WELL DRILLING, STRUCK AGAINST, BROKEN CABLE, FALL, FALL PROTECTION, STRUCK BY, TWO-BLOCKING, INATTENTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 713271 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close