Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14237341 - Employee killed in fall through broken ceiling panel

Accident Summary Nr: 14237341 -- Report ID: 0626600 -- Event Date: 03/12/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
89301603/13/198517420Cold Spaces Inc

Abstract: On Monday, March 11, 1985, Employee #1 climbed a tubular welded frame scaffold to access the top of an insulated ceiling panel. This ceiling panel had been cut and grooved on March 10, 1985, but was not yet fully installed. The foreman had instructed the employees to erect more vertical wall panels; they needed to finish one bay compartment so that the iron workers could start working. The 24 ft ceiling panel had two 1 in. undercuts that were 10 ft 10 3/4 in. apart, matching the spacing of the vertical panels. The tops of the wall panels were intended to fit into the ceiling panel's undercut grooves, but the ceiling panel had not yet been properly positioned over the vertical panels. Because the undercuts were not positioned, the insulated ceiling panel was unstable, not securely supported by the vertical panels. When Employee #1 mounted the insulated ceiling panel to begin work, his weight caused the panel to break. He fell approximately 23 ft to the concrete floor, striking the back of his head against a steel channel that was lying on the floor. He was killed.

Keywords: HEAD, UNSECURED PANEL, STRUCK AGAINST, CONSTRUCTION, EQUIPMENT FAILURE, CEILING PANEL, UNSTABLE SURFACE, FALL, FALL PROTECTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 893016 Fatality Concussion Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close