Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14236780 - 4 EMPLOYEES EXPOSED TO CHLORINE GAS

Accident Summary Nr: 14236780 -- Report ID: 0953210 -- Event Date: 07/30/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
10461172807/31/198749530E T I Group International
Inspection NrDate OpenedSICNAICSEstablishment Name
10461171007/31/198736690Bently Nevada - Main Plant

Abstract: EMPLOYEES #1 THROUGH #4 WERE DECOMMISSIONING AN ELECTROPLATING PRODUCTION LINE. THE ACIDS AND CAUSTIC STRIPPING SOLUTIONS WERE BEING TRANSFERRED TO 55 GALLON DRUMS FOR DISPOSAL. ENDPLATE AD482, CONTAINING SULFURIC ACID AND AMMONIUM CHLORIDE, WAS DRAINED INTO A RECENTLY WASHED 55 GALLON DRUM. THE ENDPLATE AD482 REACTED WITH RESIDUAL WATER, CREATING EXCESSIVE HEAT AND PRESSURE. THE REACTION RELEASED CHLORINE GAS FROM THE SOLUTION AND THE RESULTING PRESSURE CAUSED THE SEALED DRUM TO EXPLODE.

Keywords: RESPIRATORY, WORK RULES, INHALATION, CHLORINE, EXPLOSION, CHEMICAL REACTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 104611728 Non Hospitalized injury Other Chemical technicians
2 104611728 Non Hospitalized injury Other Chemical technicians
3 104611728 Non Hospitalized injury Other Chemical technicians
4 104611728 Non Hospitalized injury Other Chemical technicians
5 104611710 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.