Accident Summary Nr: 14234355 - EMPLOYEE KILLED WHEN STRUCK BY FALLING CONCRETE WALL PANEL

Accident Summary Nr: 14234355 -- Report ID: 0627700 -- Event Date: 03/25/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
10027719304/08/198617410Bill Thomas Masonry
Inspection NrDate OpenedSICNAICSEstablishment Name
10027715103/25/198615420Derrick Construction Company
Inspection NrDate OpenedSICNAICSEstablishment Name
10027716903/26/198617710Bond Builders Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
10027718504/08/198617310Hames Electric Inc

Abstract: At approximately 1:15 p.m. on March 25, 1986, Employee #1 was instantly killed when a precast concrete wall panel fell onto him. Employee #1 and three iron workers were prepared to lift three precast concrete wall panels along the south wall of a building. The work schedule for the day was to hoist each panel and place them going from east to west and weld them at the top. They were then tasked with detaching them from the crane, align each panel and weld it at the bottom. They were to then permanently attach it to the structure. At some time later during the day all panels were allowed to stand without additional bracing or supporting. During the alignment process Employee #1 and two iron workers worked in the approximately one-and- half-foot-deep ditch directly underneath the suspended panels. When the panels seemed to be approximately aligned the iron workers left the ditch while Employee #1 attempted to return to his tripod on the east corner of the existing structure. The first panel from the west corner collapsed followed by the second panel which struck Employee #1 in the head crushing and killing him instantly. The third panel also failed seconds later. The three panels collectively weighed more than 15,000 lbs.

Keywords: PRECAST, STRUCK BY, CONCRETE FORM WORK, PANEL, IRON WORKER, CONCRETE, CONCRETE PANEL, TRENCH, CRUSHED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 100277193 Occupation Not Listed
2 100277151 Occupation Not Listed
3 100277169 Fatality Fracture Occupation not reported
4 100277185 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close