Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14232300 - EMPLOYEES DIE FROM CARBON DIOXIDE SPILL

Accident Summary Nr: 14232300 -- Report ID: 0316400 -- Event Date: 06/18/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
10118256606/18/199033530Ravenswood Aluminum Cororation

Abstract: Employees #1 and #2, plant security guards, descended a stairway to the basement underneath a cold rolling mill to reset a carbon dioxide extinguishing system. The system had been triggered when a small fire at the mill had broken out six hours earlier. These two employees knew there was a known concentration of carbon dioxide in the basement but left their self contained breathing apparatus units in their vehicle and took one self rescuer with them. They were discovered 30 minutes later at the bottom of the stairway and all efforts to revive them failed. Employee #1 and #2 were pronounced dead at Jackson General Hospital.

Keywords: FIRE EXT SYSTEM, ASPHYXIATED, FIRE EXTINGUISHER, FIRE, SCBA, CARBON DIOXIDE, SPILL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101182566 Fatality Asphyxia Protective service occupations, n.e.c.
2 101182566 Fatality Asphyxia Protective service occupations, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close