Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 142285.015 - Employee is killed by explosion

Accident Summary Nr: 142285.015 -- Report ID: 0950632 -- Event Date: 12/28/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1570353.01512/28/2021336611Adept Process Services, Inc.

Abstract: On December 21, 2021, APS hired a cleaning contractor to pump out residual fuel and to clean the fuel tank of a boat (8MSC1606). It had a 250-gallon capacity (gasoline). The cleaning contractor cleaned the tank by accessing an approximate two inch hole in the tank. The contractor used acetone (a flammable substance) soaked rags attached to a wire to clean the tank. Due to the metal baffles that separated the interior of the tank into nine compartments, the majority of the surfaces on the interior of the tank were not cleaned. The tank was removed by APS the same day and placed on wooden saw horses. APS conducted an initial pressure test on the fuel tank and discovered that there was a pin-hole leak in the vent connection of the tank. Employee #1 was notified that his services were needed to make the repair on the fuel tank on December 27, 2021. At 9:50 a.m. on December 28, 2021, Employee #1 set up his welding operation and area and commenced to weld (TIG). Shortly upon beginning to weld, the tank exploded. The blast caused the tank to forcefully strike Employee #1. The blast caused the 1/4-inch aluminum lid to separate from the rest of the tank and land on the roof of an adjacent business. Employee #1 sustained major head trauma as a result of the explosion. Employee #1 was transported to a hospital, where he was pronounced dead. There are several factors that contributed to the accident. APS permitted hot work to be done on the fuel tank without the tank being adequately purged and without any testing for the flammability of gasoline vapors. APS did not designate an area free from fire hazards for the hot work and did not post an effective Fire Watch. The employer was issued a Willful-Serious-Accident related citation [CCR T8 8355(g)] for not having the tank tested and certified by a Marine Chemist.

Keywords: Acetone, Blunt force trauma, Explosion, Flammable Vapors, Fuel Tank, Gasoline, Head, Hot Work, Struck By, Welder, Welding

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1570353.015 39 M Fatality Welders and cutters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close