Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14223713 - FOUNDRY EXPLOSION

Accident Summary Nr: 14223713 -- Report ID: 0551800 -- Event Date: 12/17/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
1473335612/19/198433210Dalton Foundries Inc

Abstract: ON DECEMBER 17, 1984, AT 8:05 AM, EMPLOYEE #1 WAS WORKING HIS REGULARLY ASSIGNED JOB AS AN IRON POURER FOR THE HERMAN TWO AREA OF DALTON FOUNDRIES INC. HE WAS IN THE PROCESS OF PIGGING GRAY IRON INTO AN AURORA HOPPER FROM AN 1,800 POUND LADLE. HE HAD POURED ABOUT 100 POUNDS IN WHEN THERE WAS A SMALL EXPLOSION. HE MOVED BACK FROM THE TUB AND A SPLIT SECOND LATER THERE WAS A HUGE EXPLOSION WHICH BLEW THE TUB APART AND AMPUTATED BOTH HIS LEGS ABOVE THE KNEES. THE REST OF HIS BODY WAS BADLY BURNED. HE DIED ON DECEMBER 24, 1984. EMPLOYEE #2 WAS APPROXIMATELY 500 FEET FROM THE AREA WHEN THE EXPLOSION TOOK PLACE. HE WAS WALKING THROUGH THE DEPARTMENT ON HIS WAY TO A BREAK ROOM. HE GOT SOME DIRT PARTICLES IN HIS EYES FROM THE AIRBORNE DIRT AND DUST. HIS EYES WERE WASHED OUT AT THE HOSPITAL AND HE RETURNED TO WORK THE SAME DAY.

Keywords: BURN, EYE, AMPUTATED, DUST, EXPLOSION, IRON, FOUNDRY, LEG

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 14733356 Fatality Amputation Molding and casting machine operators
2 14733356 Non Hospitalized injury Foreign Body Ineye Misc. metal & plastic processing machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close