Accident Summary Nr: 14223440 - ELECTRIC SHOCK - CONTACT WITH WELDING ELECTRODE THRU GLOVE

Accident Summary Nr: 14223440 -- Report ID: 0551800 -- Event Date: 08/16/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
272247808/20/198517910Hoosier Harvestore Systems Inc

Abstract: AN EMPLOYEE WAS REPAIRING THE STEEL FLOOR OF A HARVESTORE STEEL SILO WITH A DAYTON PORTABLE ARC WELDER (MODEL NUMBER 32750-B). HE WAS ABOUT 10 FEET INSIDE THE SILO AND WAS WEARING LEATHER GLOVES AT THE TIME. IT WAS HUMID, AND THE LEATHER GLOVES WERE WET. THE EMPLOYEE WAS ELECTROCUTED AS HE INSERTED A WELDING ROD INTO THE ENERGIZED ELECTRODE HOLDER. ONE OF THE WET LEATHER GLOVES CONDUCTED CURRENT TO THE WEDDING BAND ON HIS LEFT RING FINGER.

Keywords: E GI II, ELEC PROTECT EQUIP, ELECTRICAL, GLOVE, ELECTROCUTED, WELDER, WELDING, WELDING ELECTRODE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2722478 Fatality Electric Shock Farm equipment mechanics

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.