Accident Summary Nr: 14223135 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU AERIAL LIFT

Accident Summary Nr: 14223135 -- Report ID: 0551800 -- Event Date: 06/27/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
1474260506/28/198407830Townsend Tree Service

Abstract: AN EMPLOYEE IN AN AERIAL LIFT WAS TRIMMING A BRANCH OF A LIVE WALNUT TREE ALONGSIDE A ROAD. THE BOTTOM OF THE BUCKET FROM WHICH HE WAS WORKING CONTAINED WET DEBRIS TO A DEPTH OF ABOUT 1.5 INCHES. AS HE STARTED TO CUT THE BRANCH, THE BUCKET CAME INTO CONTACT WITH A 7200-VOLT OVERHEAD POWER LINE. IT IS BELIVED THAT THE EMPLOYEE POSITIONED THE BUCKET SO THAT THE OVERHEAD LINE WAS CLOSE ENOUGH TO THE BUCKET'S DRAINAGE HOLE TO ALLOW CURRENT TO FLOW THROUGH THE WET DEBRIS. THE CURRENT PASSED FROM THE POWER LINE THROUGH THE DEBRIS, THE EMPLOYEE, AND THE CHAINSAW HE WAS HOLDING TO THE LIVE TREE, WHICH CONDUCTED THE CURRENT TO GROUND. THE EMPLOYEE WAS ELECTROCUTED.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, E GI IA, TREE TRIMMING, AERIAL LIFT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 14742605 Fatality Electric Shock Supervisors, forestry and logging workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close