Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14219463 - Employee killed, another injured in storage tank explosion

Accident Summary Nr: 14219463 -- Report ID: 0626600 -- Event Date: 01/28/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
10945152601/28/199351690Khempak Industries, Inc.

Abstract: On or about January 28, 1993, Employee #1, a contract welder, was repairing and replacing flanges on storage tanks in order to install a closed ventilation system. The storage tanks contained sodium sulfide, which reacts with acid to generate hydrogen sulfide gas. This highly flammable gas accumulated in a vapor space. Prior to the accident, a tank flashed while being cut or welded into by the employee. When a lighted torch was brought in proximity, the tank ruptured. Employee #1 died. Employee #2 had gone up on a tank to tell Employee #1 not to cut into the tank when the tank exploded. Employee #2 was hospitalized.

Keywords: FLAMMABLE VAPORS, HYDROGEN SULFIDE, WELDER, STORAGE TANK, RUPTURE, TORCH, EXPLOSION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 109451526 Fatality Other Occupation not reported
2 109451526 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.