Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14215842 - EMPLOYEES EXPOSED TO METHYLENE CHLORIDE IN CONFINED SPACE

Accident Summary Nr: 14215842 -- Report ID: 0454510 -- Event Date: 07/16/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
319945207/17/198617210Harrison Contractors
Inspection NrDate OpenedSICNAICSEstablishment Name
319947807/23/198641190Laurens County Emergency Medical Service
Inspection NrDate OpenedSICNAICSEstablishment Name
319944507/18/198649530Gsx Services Inc., Ert Group
Inspection NrDate OpenedSICNAICSEstablishment Name
319946007/23/198628990Chemco International, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
319950207/31/198641190Greenwood County Ems
Inspection NrDate OpenedSICNAICSEstablishment Name
319951008/04/198649530Bryson Industrial Services, Inc.

Abstract: EMPLOYEE #1, ALONG WITH OTHERS, WAS REMOVING PAINT OVERSPRAY FROM THE FLOOR OF A PUMPING PIT. A PAINT STRIPPER CONTAINING 66 PERCENT METHYLENE CHLORIDE, AND SMALLER PERCENTAGES OF TOLUENE, METHYL ETHYL KETONE, ACETONE AND METHANOL WAS BEING USED. THE FLOOR WAS 35 FEET BELOW THE GROUND IN A 35 BY 24 FOOT PIT WITH AN ENCLOSED BUILDING ABOVE IT. NO MECHANICAL VENTILATION WAS PROVIDED. A STRONG BUILDUP OF FUMES CAUSED THE WORKERS TO EVACUATE. EMPLOYEE #1 RETURNED TO THE PIT. HE WAS OVERCOME BY THE FUMES AND WAS KILLED. EMPLOYEE #2, AN EMERGENCY MEDICAL EMPLOYEE, ATTEMPTED TO RESCUE EMPLOYEE #1. HE WAS HOSPITALIZED BECAUSE OF HIS EXPOSURE TO THE FUMES. THIS EVENT WAS CAUSED BY IMPROPER ENTRY INTO A CONFINED SPACE CONTAINING HAZARDOUS LEVELS OF METHYLENE CHLORIDE.

Keywords: RESPIRATORY, TOXIC FUMES, VENTILATION, METHYLENE CHLORIDE, WORK RULES, INHALATION, CONFINED SPACE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 3199452 Fatality Asphyxia Painters, construction and maintenance
2 3199478 Hospitalized injury Asphyxia Health aides, except nursing
3 3199445 Occupation Not Listed
4 3199460 Occupation Not Listed
5 3199502 Occupation Not Listed
6 3199510 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.