Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14214589 - HEAD CRUSHED IN TURBINE BATCH MIXER

Accident Summary Nr: 14214589 -- Report ID: 0454711 -- Event Date: 01/16/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
324500801/16/198635310Fletcher Concrete Company

Abstract: EMPLOYEE #1 AND HIS ASSISTANT WERE CLEANING A TURBINE BATCH MIXER. EMPLOYEE #1 WAS APPARENTLY PARTLY INSIDE THE MIXER WHEN HE TOLD HIS ASSISTANT TO START IT UP. WHEN THE MIXER STARTED, THE EMPLOYEE BECAME ENTANGLED IN THE PADDLE ARM AND WAS CRUSHED WHEN HIS HEAD STRUCK THE BOTTOM OF THE MATERIAL CHUTE.

Keywords: HEAD, CONFINED SPACE, CLEANING, MIXER, LOCKOUT, CRUSHED, ENTANGLED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 3245008 Fatality Fracture Mixing and blending machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.