Accident Summary Nr: 14214464 - FORK LIFT OPERATOR KILLED BY FALLING BUNDLE OF LUMBER

Accident Summary Nr: 14214464 -- Report ID: 0454715 -- Event Date: 05/29/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
1517234902/07/198524260Bruce Hardwood Floors
Inspection NrDate OpenedSICNAICSEstablishment Name
1517115005/29/198524260Bruce Hardwood Floors

Abstract: On May 29, 1985, Employee #1, a fork lift operator, was helping unload lumber from a truck. The lumber was banded into bundles of random length measuring approximately 30 inches by 42 inches by 8 feet to 12 feet and weighing 5,000 to 6,000 pounds. Employee #1 was near stacked bundles placing a 4-inch by 4-inch piece of wood on the ground to support a bundle. He was crushed and killed when a bundle, from a stack four bundles high, fell onto him.

Keywords: IND TRK OPERATOR, CRUSHED, INDUSTRIAL TRUCK, FALLING OBJECT, LUMBER STACK, UNSTABLE POSITION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 15172349 Fatality Other Industrial truck and tractor equipment operators
2 15171150 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.