Accident Summary Nr: 14211387 - FALL THROUGH ROOF

Accident Summary Nr: 14211387 -- Report ID: 0352440 -- Event Date: 10/03/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
1481344810/03/198417910Beltex Corp

Abstract: EMPLOYEES WERE CUTTING SKYLIGHT AND AIR INTAKE HOLES IN A 22 GAUGE STEEL ROOF, WHOSE PANELS MEASURED APROX 26' X 4'. THE OPENINGS WERE 72" X 48". THE TWO WITNESSES HAD JUST CUT TWO PARALLEL 72" LINES WHEN THE SAW BLADES BECAME DULL. THEY CHANGED ONE BLADE BUT WERE UNABLE TO FREE THE FROZEN ARBOR NUT ON THE SECOND. EMPLOYEE #1, THE FOREMAN, CAME OVER TO ASSIST. THERE WAS AN OVERLAP OF TWO SHEETS OF STEEL APPROXIMATELY 24 1/2" FROM THE START OF THE CUTS. AT THESE SEAMS EVERY 5' WAS A 1/4"X 2" BOLT USED TO HOLD THE PANELS TOGETHER BETWEEN THE JOISTS. THIS BOLT WAS APPROX 8" FROM THE EAST CUT. ALONG THE JOISTS THE DECKING WAS SECURED BY THE SAME SIZE BOLTS EVERY 12". THE JOISTS RAN N.TO S.WHILE PANELS RAN E.TO W. WITNESSES WERE AT THE NW CORNER OF THE CUT. THE INJURED WAS ON THE W SIDE APPROX 24" FROM THE START OF THE CUT. IN ORDER TO SECURE BETTER FOOTING THE INJURED STEPPED BACK AND ONTO THE SEAM OF THE DECK PANELS. THE INJURED WEIGHED APPROX 230#. THE BOLT ON THE SEAM RIPPED OUT, OPENING THE AREA BETWEEN THE CUTS APPROX. 47 1/2" SIMILAR TO A TRAP DOOR. THE INJURED FELL THROUGH AND DOWN TO THE 6" THICK CONCRETE DECK BELOW APPROX 16'7".THIS MEASUREMENT WAS TAKEN WITH ALUFKIN 50' STEEL TAPE & THE BLUEPRINT LABELED "BRANDON I LOT 9, PROJECT 0101.9, DRAWING S-2. THE EQUIPMENT WAS A STEHL METAL SAW SER #TS-30. INJURED SUSTAINED 2 BROKEN WRISTS, BRUISES TO THE HEART & LUNGS AND CHIPPED LEFT CHEEKBONE. EXACT LOCATION WAS BETWEEN SUPPORTS D-1 E/E-1, SLIGHTLY SOUTH OF D-1, 15' 10 1/2" FROM THE EDGE OF THE SOUTH WALL. OVERLAP OF PANELS WAS 1 1/2" AT THE BOTTOM & 3" AT THE TOP. JOIST SEPARTION 5'4" C TO C. CAUSE: FAILURE OF FOREMAN TO RECOGNIZE A HAZARDOUS CONDITION.

Keywords: FRACTURE, ROOF, FALL, ROOF OPENING, CONTUSION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 14813448 Hospitalized injury Fracture Structural metal workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close