Accident Summary Nr: 14204002 - EMPLOYEE ASPHYXIATED BY OVERHEATED AIR COMPRESSOR

Accident Summary Nr: 14204002 -- Report ID: 1054194 -- Event Date: 06/14/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
1505353106/14/198414290Conser Quarry Inc

Abstract: An employee of Conser Quarry Incorporated was working alone sandblasting a Caterpillar vehicle, prior to painting it. While doing the work, the employee was wearing a supplied-air helmet, with breathing air provided by a more than 20 year old, Schramm oil-lubricated air compressor. Because the air compressor lacked a high temperature alarm, or a carbon monoxide alarm, when it overheated, it ignited oil mist and oil residue inside the compressed air tank. The employee died of asphyxiation due to insufficient oxygen and elevated levels of carbon monoxide.

Keywords: OXYGEN DEFICIENCY, ASPHYXIATED, SANDBLASTING, CARBON MONOXIDE, RESPIRATOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 15053531 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.