Accident Summary Nr: 14202345 - CONCRETE FLOOR SLAB COLLAPSE WHILE BEING REMOVED FROM BELOW

Accident Summary Nr: 14202345 -- Report ID: 1054112 -- Event Date: 03/13/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
10532068303/13/198717710Accurate Concrete Cutting Inc

Abstract: On March 13, 1987, three employees were cutting and removing a section of concrete slab flooring in a paper mill. The section being removed was approximately 30 ft by 10 ft with a thickness of 8 inches. Due to the paper machine being located on the floor and being kept in operation during this process, the work being done by the three employees was being done from below or under the floor being removed. The employees were cutting, coring and removing this 30 ft by 10 ft section in approximately 6 ft by 4 ft sections. Ten of these sections had been successfully removed prior to the accident. During the removal of the last two sections, an unplanned collapse occurred resulting in approximately a 6 ft by 10 ft section of floor slab falling and striking the three employees working below it. The three employees were on scaffolding or a staging work platform. It is possible that this accident occurred during the process of removing the ceiling jacks or braces and installation of the forklift unit which was being used to remove sections. Employee #1 was seriously injured sustaining a severely broken left leg and right ankle. Employee #2 sustained minor bruises and a broken rib as he pushed Employee #3 clear of the falling slab. Causal factors included lack of written demolition plan, lack of adequate underpinning and possible lack of adequate supervision on site at the time of the accident. Also, a lack of rebar at the breaking point of the concrete slab was found.

Keywords: CONCRETE SLAB, FRACTURE, REBAR, UNDERPINNING, COLLAPSE, CEILING, INDUSTRIAL TRUCK, PAPER MACHINE, CONTUSION, SCAFFOLDING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 105320683 Hospitalized injury Fracture Construction trades, n.e.c.
2 105320683 Non Hospitalized injury Bruise/Contus/Abras Construction trades, n.e.c.
3 105320683 Non Hospitalized injury Bruise/Contus/Abras Construction trades, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.