Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14200018 - FALL FROM WALL PANEL

Accident Summary Nr: 14200018 -- Report ID: 0352420 -- Event Date: 09/24/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
1485986211/08/198417710Elion Concrete Inc

Abstract: EMPLOYEE #1 WAS INSTRUCTED TO NAIL A BULK HEAD TO A WALL PANEL. THIS IS A PRE-FORMED PANEL WHICH IS PART OF THE 2ND STORY WALL (ELEVATOR SHAFT WALL). EMPLOYEE #1 FREE CLIMBED OUT ONTO THE SIDE OF THE WALL PANEL. THERE WAS NO WORK PLATFORM TO STAND ON. HE WAS WEARING A SAFETY BELT AND LANYARD. HE HAD CONNECTED HIS LANYARD TO A SPUD WRENCH WHICH HE HAD PLACED THROUGH A HOLE IN THE PANEL WALL. AFTER NAILING A SECTION OF THE BULK HEAD, HE STARTED TO MOVE TO ANOTHER SIDE OF THE PANEL. WHILE DOING THIS HIS SPUD WRENCH SLIPPED OUT OR THE LANYARD SLIPED OUT. HE FELL APPROX. 24' INTO AN ELEVATOR PIT. HE RECEIVED A BROKEN RIB AND A BROKEN VERTABRA.

Keywords: FRACTURE, SAFETY BELT, LANYARD, RIB, FALL, VERTEBRA

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 14859862 Hospitalized injury Fracture Carpenters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close