Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14196885 - SKIN BURNS FROM EXPOSURE TO GASEOUS ANHYDROUS AMMONIA

Accident Summary Nr: 14196885 -- Report ID: 0352450 -- Event Date: 04/21/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
1481576504/23/198559840Tri-Gas & Oil Company, Incorporated

Abstract: EMPLOYEE #1 WAS UNLOADING LIQUID ANHYDROUS AMMONIA AT THE CROP PRODUCTION SERVICE LOCATION IN HURLOCK, MARYLAND. AS THE PUMP ON THE TANK TRAILER WAS TURNED ON, THE TRANSFER HOSE WHICH CARRIED THE ANHYDROUS AMMONIA RUPTURED. THE RUPTURE ALLOWED GASEOUS AMMONIA TO ENGULF THE EMPLOYEE. HE SUFFERED SECOND AND THIRD DEGREE BURNS OVER 38% OF HIS BODY. THE HOSE WAS LISTED FOR USE WITH LP GAS BUT NOT FOR ANHYDROUS AMMONIA. THE EMPLOYEE WAS TRAINED IN THE SAFE HANDLING OF BOTH LP GAS AND ANHYDROUS AMMONIA. NO PROTECTIVE CLOTHING WAS IN USE (EXCEPT FOR GLOVES). NO RESPIRATORY PROTECTION WAS AVAILABLE FOR THE EMPLOYEE. THE HOSE WAS MANUFACTURED BY THE ELECTRIC HOSE AND RUBBER COMPANY (NOW OWNED BY DAYCO CORP. OF OCOLA, FL).

Keywords: BURN, PPE, HOSE, RUPTURE, ANHYDROUS AMMONIA, SKIN, RESPIRATOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 14815765 Hospitalized injury Burn(Chemical) Truck drivers, heavy

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close