Accident Summary Nr: 14195283 - EMPLOYEE INJURED IN A FALL FROM A METAL STRUCTURE
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 2868511 | 06/03/1985 | 1791 | 0 | G&G Welding |
Abstract: On May 24, 1985, an employee was installing metal decking when he decided to carry a 0.625 in. piece of angle iron (dimensions of 3 in. by 3 in. by 4ft at a 90 degree bend) from his initial position to another location for installation. He traversed a 6 in. by 15 ft I-beam when he lost his footing and fell approximately 15 ft to the ground. The employee was wearing a safety belt, but he failed to tie it off. He sustained injures with a fracture to his right forearm and pelvis. He had 4 years of experience as an iron-worker and had received training in safe work practices.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 2868511 | Hospitalized injury | Fracture | Structural metal workers |