Accident Report Detail

Accident Summary Nr: 14194922 - EMPLOYEE'S LEG FRACTURED DUE TO FALL FROM STEEL DECKING

Accident Summary Nr: 14194922 -- Report ID: 0352440 -- Event Date: 02/13/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
286651503/12/198517910Janco Enterprises Inc.

Abstract: A structural metal employee was standing on a bundle of steel decking approximately 3 ft wide 25 ft above the ground in an open bay area. The steel decking weighed two tons and was supported by three 40-ft long open web joists (Type 24 H 8). None of the web joists were properly secured to prevent collapsing. The employee was standing on the end of the bundle closes to the exposed edge of the bay. A second similar bundle of decking was hoisted by crane and placed onto the opposite end of the bundle the employee was standing on. The web joists failed due to the extra weight and the fact they were not secured. The employee fell 25 ft into mud. He sustained fractures to both legs and was hospitalized.

Keywords: DECKING, FRACTURE, JOIST, STEEL, FALL, LEG

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2866515 Hospitalized injury Fracture Structural metal workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close