Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 141581.015 - Employee dies from head trauma after aerial lift rolls over

Accident Summary Nr: 141581.015 -- Report ID: 0521700 -- Event Date: 11/29/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1566053.01511/30/2021339999Faciliserv, Inc.

Abstract: At 1:13 p.m. on November 29, 2021, Employee #1, the lead field service technician, was repairing a vinyl curtain in the gym of a high school. Employee #1 was raised in an elevated platform (i.e., bucket/basket) of a Genie Model Number AWP-25S lift that was without power, while a coworker, a field technician, was on the ground pushing the lift. The lift rolled over and Employee #1 fell from the elevated platform, approximately 28 feet 5 inches, to the ground below. Employee #1 was transported to a hospital, where he died from head trauma.

Keywords: Aerial Lift, Bucket , Elevated Work Platform, Fall, Fall From Elevation, Head, Roll-Over

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1566053.015 29 M Fatality Aerial Lift Operator

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.