Accident Summary Nr: 141177.015 - Employee is killed in fall off ladder

Accident Summary Nr: 141177.015 -- Report ID: 0552651 -- Event Date: 11/12/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1564111.01511/22/2021236220Commercial Construction Management, Llc

Abstract: At 8:00 a.m. on November 12, 2021, Employee #1 was inspecting a patch installed by roofers to fix a leak. Employee #1 was using extension ladder to access the roof. Once on the roof, Employee #1 wanted the ladder to extend higher above the upper landing area. Employee #1 pulled the top of the ladder to extend it approximately 1 rung. However, the latches that lock the top and bottom halves of the ladder together after extension did not full engage. When Employee #1 got back on the ladder to begin descent, the ladder fell down 1 rung and the latches slammed down on the rung. The momentum of the impact caused the ladder to pull away from the building and tip over, causing Employee #1 to fall head first 15 feet to the ground below. Employee #1 suffered head and spinal injuries, resulting in death.

Keywords: Building, Descending Ladder, Extension Ladder, Fall, Fall From Elevation, Head, Ladder, Roof, Roofer, Spine, Tips Over
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition   2 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Construction
1 1564111.015 58 M Fatality Distance of Fall: 15 feet
Worker Height Above Ground/Floor: 15 feet
Cause:
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.