Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 141136.015 - Two employees sustain hot water burns from ruptured hot wate

Accident Summary Nr: 141136.015 -- Report ID: 0729300 -- Event Date: 11/08/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1563159.01511/10/2021331523Spartan Lmp

Abstract: At 4:00 p.m. on November 8, 2021, Employee #1 and Employee #2 were conducting a visual inspection of their equipment. They were standing 5 feet to 6 feet away from the hot water pressure hoses. Then, one of the hoses ruptured and struck Employee #1 and Employee #2 with hot water on their abdomens and right forearms. They both sustained second-degree burns and were taken to the hospital. Employee #1 was released the same day. Employee #2 was hospitalized overnight for further observation.

Keywords: Abdomen, Arm, Burn, Forearm, Hot Water, Scald, Struck By, Water, Water Hose

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1563159.015 42 M Hospitalized injury Mechanical engineers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.