Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 141082.015 - Employee fractures, cuts fingers from contact with sawblade

Accident Summary Nr: 141082.015 -- Report ID: 0950621 -- Event Date: 07/21/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1547198.01508/12/2021212321Sierra Foothills Construction Company

Abstract: At 9:30 a.m. on July 21, 2021, an employee working as a carpenter for a general contractor was working on a residential construction project. The employee had been employed by the company for four years and had 26 years of experience in the industry. The employer only had the employee and a coworker, the project manager, working on site at the time. The employee was operating a Bosch Table Saw to rip 2-inch by 4-inch by 10-foot dry wood boards into 1-inch by 2-inch pieces for a deck edge. The employee had been ripping the boards for a couple of hours using a push stick to feed the wood into the saw. The employee was pushing with his right hand and using his left hand to push the wood against the fence. The employee had his left thumb hooked onto the edge of the table to keep his hand from traveling. The hood guard, anti-kickback device and riving knife were all installed on the table saw. The employee doesn't recall what happened. His first recollection is his left hand being in contact with the sawblade. There were no witnesses to the incident. The employee transported to the hospital, where he was admitted to treat a laceration and proximal phalanx fracture on his left hand index finger and distal phalanx fracture on his left thumb. On July 22, 2021, the employee was released from the hospital.

Keywords: Carpenter, Construction, Contact, Cutting, Finger, Fracture, Hand, Laceration, Machine operator, Push Stick, Pushing, Residential Construction, Rip, Sawblade, Table Saw, Thumb, Unknown, Wood Board
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling New project or new addition   2

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1547198.015 60 M Hospitalized injury Carpenter Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Other Activities-Post Decking Detail Work
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.