Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 140689.015 - Employee amputates two fingertips in horizonal press

Accident Summary Nr: 140689.015 -- Report ID: 0626300 -- Event Date: 10/14/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1561093.01510/29/20213323124front Engineered Solutions, Inc.

Abstract: At 1:50 p.m. on October 14, 2021, an employee was using a horizontal press to bend metal anchors measuring 10.5 inches by 6 inches. When the employee tried to correct a bend by straightening the part, his fingers became caught in a pinch point between the die and the part. The employee's middle and index fingertips were amputated. The employee was treated without hospitalization.

Keywords: Bolt, Caught In, Die, Finger, Fingertip, Nip Point, Press

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1561093.015 43 M Non Hospitalized injury Welders and cutters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.