Accident Summary Nr: 140521.015 - Employee suffocates when engulfed in grain bin, later dies

Accident Summary Nr: 140521.015 -- Report ID: 0552700 -- Event Date: 10/22/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1560133.01510/21/2021424690103658 - New Age Cryo

Abstract: On October 20, 2021, an employee entered a grain storage unit that had build up on the walls to clean it out. A coworker serving as the entry attendant lowered him on a boatswain chair. As he worked to clean out the chutes at the bottom of the storage unit, grain came loose off the walls and engulfed him suffocating him. The employee was taken to the hospital immediately but died on October 22, 2021 due to oxygen deprivation.

Keywords: Asphyxiated, Bosun Chair, Brain, Chute, Cleaning, Confined Space, Engulfed, Entry Permit, Grain, Grain Bin, Hazard Assessment, Inhalation, Lack of oxygen, Lung, Misjudgment, Misjudgment of Hazardous Situation, Oxygen, Oxygen Deficiency, Storage Bin, Suffocated, Unauthorized, Unauthorized Entry, Wall

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1560133.015 27 M Fatality Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.