Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 140158.015 - Employee is found killed with head in confined space

Accident Summary Nr: 140158.015 -- Report ID: 0950615 -- Event Date: 10/12/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1557844.01510/12/2021312130Dry Creek Vineyard Inc.

Abstract: At 2:00 p.m. on October 12, 2021, an employee was working on top of a fermentation tank (a confined space), preparing to install a spray nozzle and attach it via hose to the pump-over riser to begin a pump over. The employee opened the fermentation tank and was found laying on the platform with his upper body inside of the tank. The employee was killed due to a fatality hazardous atmosphere.

Keywords: Chemical, Chemical Vapor, Confined Space, Misjudgment of Hazardous Situation, Unresponsive

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1557844.015 61 M Fatality Production helpers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.