Accident Summary Nr: 140008.015 - Employee is killed when struck by falling dock leveler ramp

Accident Summary Nr: 140008.015 -- Report ID: 0626600 -- Event Date: 10/08/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1557065.01510/08/2021493120Heb Blalock Warehouse

Abstract: At 11:30 a.m. on October 8, 2021, an employee was performing maintenance to a mechanical dock leveler and was testing the equipment when a bolt sheared off causing a ramp to close. The employee's head was caught under the ramp and was crushed, killing him.

Keywords: Bolt, Caught By, Caught In, Crushed, Falling Object, Fracture, Head, Loading Dock, Loading Ramp, Lockout, Lockout/Tagout, Maintenance, Material Handling, Metal, Metal Decking, PPE, Ramp, Repair, Safety Block, Sheared, Struck Against, Struck By, Testing, Unstable Position, Warehouse, Work Surface

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1557065.015 61 M Fatality Specified mechanics and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.