Abstract: At 9:15 a.m. on September 24, 2021, an employee was removing the mast of a forklift powered industrial truck (PIT) to perform maintenance on the forklift's differential when the mast fell forward and struck the employee. The employee killed from blunt force trauma to his head and chest.

Keywords: Blunt force, Blunt force trauma, Chest, Forklift, Head, Industrial Truck, Lockout, Lockout/Tagout, Maintenance, Mast, Motor Vehicle, Powered Industrial Vehicle, Struck By, Unsecured

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1554524.015 33 M Fatality Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.