Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 139110.015 - Employee is struck by board while operating chipper and inju

Accident Summary Nr: 139110.015 -- Report ID: 0316400 -- Event Date: 07/14/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1543190.01507/21/2021321113Allegheny Wood Products, Inc.

Abstract: At 11:00 p.m. on July 14, 2021, Employee #1 was operating a chipper when a board became jammed. With assistance from his supervisor and a coworker on the chipper side, Employee #1 went behind the chipper to gain a better angle to free the jam. The board shifted suddenly, striking Employee #1 and causing contact with a nearby Fulghum Industries, Inc. Shaker Table (Model 8X8; Serial No. F1-R-877) that was in operation. Emergency services transported Employee #1 to the hospital, where he was admitted and treated for a right shoulder injury.

Keywords: Chipper, Chipping, Jammed, Shoulder, Struck Against, Struck By, Wood Chipper

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1543190.015 68 M Hospitalized injury

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.